DC and AC parameters
M95320-W M95320-R M95320-DR
Table 15. DC characteristics (M95320-W, device grade 6)
Symbol
Parameter
Test conditions
Min. Max. Unit
ILI
Input leakage
current
VIN = VSS or VCC
± 2 µA
ILO
Output leakage
current
S = VCC, VOUT = VSS or VCC
± 2 µA
ICC
Supply current
(Read)
ICC0(2)
Supply current
(Write)
VCC = 2.5 V, fC = 5 MHz,
C = 0.1 VCC/0.9 VCC, Q = open
VCC = 2.5 V, fC = 10 MHz,
C = 0.1 VCC/0.9 VCC, Q = open
VCC = 3.0 V, fC = 10 MHz
C = 0.1 VCC/0.9 VCC, Q = open
VCC = 5.5 V, fC = 20 MHz,
C = 0.1 VCC/0.9 VCC, Q = open
During tW, S = VCC, 2.5 V < VCC < 5.5 V
3
2(1)
mA
4
5(1)
5
mA
ICC1
VIL
VIH
VOL
VOH
VRES(2)
Supply current
(Standby)
Input low voltage
Input high voltage
Output low voltage
Output high voltage
Internal reset
threshold voltage
S = VCC, VCC = 5.5 V
VIN = VSS or VCC
S = VCC, VCC = 5.0 V
VIN = VSS or VCC
S = VCC, VCC = 2.5 V
VIN = VSS or VCC
IOL = 1.5 mA, VCC = 2.5 V
VCC = 2.5 V and IOH = 0.4 mA or
VCC = 5 V and IOH = 2 mA
3(1)
2
µA
1(3)
–0.45 0.3 VCC V
0.7 VCC VCC+1 V
0.4
V
0.8 VCC
V
1.0(4) 1.65(5) V
1. Only for the device identified by process letter K.
2. Characterized only, not tested in production.
3. 2 µA with the device identified by process letter K.
4. 0.7 V with the device identified by process letter K.
5. 1.3 V with the device identified by process letter K.
34/48