Ethernet: Three-Speed Ethernet, MII Management
Table 32. MII Management DC Electrical Characteristics Powered at 2.5 V (continued)
Parameter
Symbol
Conditions
Min
Input high current
IIH
VIN1 = LVDD
—
Input low current
IIL
VIN = LVDD
–15
Note:
1. The symbol VIN, in this case, represents the LVIN symbol referenced in Table 1 and Table 2.
Max
10
—
Table 33. MII Management DC Electrical Characteristics Powered at 3.3 V
Parameter
Symbol
Conditions
Min
Supply voltage (3.3 V)
LVDD
—
2.97
Output high voltage
VOH
IOH = –1.0 mA LVDD = Min
2.10
Output low voltage
VOL
IOL = 1.0 mA
LVDD = Min
GND
Input high voltage
VIH
—
2.00
Input low voltage
Input high current
VIL
—
—
IIH
LVDD = Max
VIN1 = 2.1 V
—
Input low current
IIL
LVDD = Max
VIN = 0.5 V
–600
Note:
1. The symbol VIN, in this case, represents the LVIN symbol referenced in Table 1 and Table 2.
Max
3.63
LVDD + 0.3
0.50
—
0.80
40
—
Unit
μA
μA
Unit
V
V
V
V
V
μA
μA
8.3.2 MII Management AC Electrical Specifications
Table 34 provides the MII management AC timing specifications.
Table 34. MII Management AC Timing Specifications
At recommended operating conditions with LVDD is 3.3 V ± 10% or 2.5 V ± 5%.
Parameter/Condition
Symbol1
Min
Typ
Max
MDC frequency
MDC period
MDC clock pulse width high
MDC to MDIO delay
MDIO to MDC setup time
MDIO to MDC hold time
MDC rise time
fMDC
—
2.5
—
tMDC
—
400
—
tMDCH
32
—
—
tMDKHDX
10
—
70
tMDDVKH
5
—
—
tMDDXKH
0
—
—
tMDCR
—
—
10
Unit
MHz
ns
ns
ns
ns
ns
ns
Notes
2
—
—
3
—
—
—
MPC8349EA PowerQUICC II Pro Integrated Host Processor Hardware Specifications, Rev. 13
32
Freescale Semiconductor