Data Sheet
ADuM3160
DIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS
This isolator is suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensured by
protective circuits. The asterisk (*) marking branded on the component denotes DIN V VDE V 0884-10 (VDE V 0884-10):2006-12 approval.
Table 5.
Description
Installation Classification per DIN VDE 0110
For Rated Mains Voltage ≤ 150 V rms
For Rated Mains Voltage ≤ 300 V rms
For Rated Mains Voltage ≤ 400 V rms
Climatic Classification
Pollution Degree per DIN VDE 0110, Table 1
Maximum Working Insulation Voltage
Input-to-Output Test Voltage, Method B1
Input-to-Output Test Voltage, Method A
After Environmental Tests Subgroup 1
After Input and/or Safety Tests
Subgroup 2 and Subgroup 3
Highest Allowable Overvoltage
Safety-Limiting Values
Case Temperature
Side 1 + Side 2 Current
Insulation Resistance at TS
Test Conditions/Comments1
VIORM × 1.875 = VPR, 100% production test, tm = 1 sec,
partial discharge < 5 pC
VIORM × 1.6 = VPR, tm = 60 sec, partial discharge < 5 pC
VIORM × 1.2 = VPR, tm = 60 sec, partial discharge < 5 pC
Transient overvoltage, tTR = 10 seconds
Maximum value allowed in the event of a failure
(see Figure 2)
VIO = 500 V
Symbol Characteristic Unit
VIORM
VPR
VPR
VTR
I to IV
I to III
I to II
40/105/21
2
560
1050
896
672
4000
V peak
V peak
V peak
V peak
V peak
TS
150
°C
IS1
550
mA
RS
>109
Ω
1 For information about tM, tTR, and VIO, see DIN V VDE V 0884-10.
600
RECOMMENDED OPERATING CONDITIONS
500
Table 6.
Parameter
Symbol Min Max Unit
400
Operating Temperature TA
−40 +105 °C
Supply Voltages1
VBUS1, VBUS2 3.0
5.5
V
300
Input Signal Rise and Fall
1.0 ms
Times
200
1 All voltages are relative to their respective grounds. See the DC Correctness
and Magnetic Field Immunity section for information about immunity to
100
external magnetic fields.
0
0
50
100
150
200
AMBIENT TEMPERATURE (°C)
Figure 2. Thermal Derating Curve, Dependence of Safety-Limiting Values
on Case Temperature, per DIN V VDE V 0884-10
Rev. C | Page 5 of 16