M25PE40
DC and AC parameters
Table 17. DC characteristics
Symbol
Parameter
Test condition
(in addition to those in Table 14)
Min. Max. Unit
ILI Input Leakage current
ILO Output Leakage current
ICC1
Standby current
(Standby and Reset modes)
ICC2 Deep Power-down current
ICC3
Operating current
(FAST_READ)
ICC4 Operating current (PW)
ICC5 Operating current (SE)
VIL Input Low voltage
VIH Input High voltage
VOL Output Low voltage
VOH Output High voltage
± 2 µA
± 2 µA
S = VCC, VIN = VSS or VCC
50
µA
S = VCC, VIN = VSS or VCC
10
µA
C = 0.1VCC/0.9.VCC at 25 MHz, Q = open
6
mA
C = 0.1VCC/0.9.VCC at 50 MHz, Q = open
8
mA
S = VCC
15 mA
S = VCC
15 mA
– 0.5 0.3VCC V
0.7VCC VCC+0.4 V
IOL = 1.6 mA
0.4
V
IOH = –100 µA
VCC–0.2
V
Table 18.
Symbol
DC characteristics (75 MHz operation, T9HX (0.11 µm) process)(1)
Parameter
Test condition
(in addition to those in Table 14)
Min.
Max. Unit
ILI Input Leakage current
ILO Output Leakage current
ICC1
Standby current
(Standby and Reset modes)
S = VCC, VIN = VSS or VCC
ICC2 Deep Power-down current
S = VCC, VIN = VSS or VCC
ICC3
Operating current
(FAST_READ)
C = 0.1VCC/0.9.VCC at 33 MHz, Q = open
C = 0.1VCC/0.9.VCC at 75 MHz, Q = open
ICC4 Operating current (PW)
S = VCC
ICC5 Operating current (SE)
S = VCC
VIL Input Low voltage
VIH Input High voltage
VOL Output Low voltage
IOL = 1.6 mA
VOH Output High voltage
IOH = –100 µA
1. Delivery of parts operating with a maximum clock rate of 75 MHz starts from week 8 of 2008.
± 2 µA
± 2 µA
50 µA
10 µA
4
mA
12 mA
15 mA
15 mA
– 0.5 0.3VCC V
0.7VCC VCC+0.4 V
0.4
V
VCC–0.2
V
47/62