M95128, M95128-W, M95128-R
8
Maximum rating
Maximum rating
Stressing the device outside the ratings listed in Table 6 may cause permanent damage to
the device. These are stress ratings only, and operation of the device at these, or any other
conditions outside those indicated in the Operating sections of this specification, is not
implied. Exposure to Absolute Maximum Rating conditions for extended periods may affect
device reliability. Refer also to the STMicroelectronics SURE Program and other relevant
quality documents.
Table 6. Absolute maximum ratings
Symbol
Parameter
Min. Max. Unit
TA
Ambient Operating Temperature
–40
130
°C
TSTG Storage Temperature
–65
150
°C
VO
Output Voltage
–0.50 VCC+0.6 V
VI
Input Voltage
–0.50 6.5
V
VCC
Supply Voltage
–0.50 6.5
V
VESD Electrostatic Discharge Voltage (Human Body model)(1) –4000 4000
V
1. AEC-Q100-002 (compliant with JEDEC Std JESD22-A114A, C1=100pF, R1=1500W, R2=500Ω).