M95128, M95128-W, M95128-R
DC and AC parameters
Table 10. AC measurement conditions(1)
Symbol
Parameter
Min.
Max.
CL
Load Capacitance
Input Rise and Fall Times
100
50
Input Pulse Voltages
0.2VCC to 0.8VCC
Input and Output Timing Reference Voltages
0.3VCC to 0.7VCC
1. Output Hi-Z is defined as the point where data out is no longer driven.
Figure 14. AC measurement I/O waveform
Input Levels
0.8VCC
Input and Output
Timing Reference Levels
0.7VCC
0.2VCC
0.3VCC
AI00825B
Unit
pF
ns
V
V
Table 11. Capacitance(1)
Symbol
Parameter
Test Condition
COUT
Output Capacitance (Q)
VOUT = 0V
Input Capacitance (D)
CIN
Input Capacitance (other pins)
VIN = 0V
VIN = 0V
1. Sampled only, not 100% tested, at TA=25°C and a frequency of 5 MHz.
Min.
Max.
8
8
6
Unit
pF
pF
pF
27/41