Ethernet:Three-Speed Ethernet, MII Management
8.3 Ethernet Management Interface Electrical Characteristics
The electrical characteristics specified here apply to the MII management interface signals management
data input/output (MDIO) and management data clock (MDC). The electrical characteristics for GMII,
RGMII, TBI and RTBI are specified in Section 8.1, “Three-Speed Ethernet Controller (TSEC)—
GMII/MII/TBI/RGMII/RTBI Electrical Characteristics.”
8.3.1 MII Management DC Electrical Characteristics
The MDC and MDIO are defined to operate at a supply voltage of 2.5 or 3.3 V. The DC electrical
characteristics for MDIO and MDC are provided in Table 28 and Table 29.
Table 28. MII Management DC Electrical Characteristics Powered at 2.5 V
Parameter
Symbol
Conditions
Min
Supply voltage (2.5 V)
LVDD
—
2.37
Output high voltage
VOH
IOH = –1.0 mA LVDD = Min
2.00
Output low voltage
VOL
IOL = 1.0 mA LVDD = Min
GND – 0.3
Input high voltage
VIH
—
LVDD = Min
1.7
Input low voltage
Input high current
VIL
—
LVDD = Min
–0.3
IIH
VIN1 = LVDD
—
Input low current
IIL
VIN = LVDD
–15
Note:
1. The symbol VIN, in this case, represents the LVIN symbol referenced in Table 1 and Table 2.
Max
2.63
LVDD + 0.3
0.40
—
0.70
10
—
Unit
V
V
V
V
V
μA
μA
Table 29. MII Management DC Electrical Characteristics Powered at 3.3 V
Parameter
Symbol
Conditions
Min
Supply voltage (3.3 V)
LVDD
—
2.97
Output high voltage
VOH
IOH = –1.0 mA LVDD = Min
2.10
Output low voltage
VOL
IOL = 1.0 mA
LVDD = Min
GND
Input high voltage
VIH
—
2.00
Input low voltage
Input high current
VIL
—
—
IIH
LVDD = Max
VIN1 = 2.1 V
—
Input low current
IIL
LVDD = Max
VIN = 0.5 V
–600
Note:
1. The symbol VIN, in this case, represents the LVIN symbol referenced in Table 1 and Table 2.
Max
3.63
LVDD + 0.3
0.50
—
0.80
40
—
Unit
V
V
V
V
V
μA
μA