Philips Semiconductors
Universal Timeslot Interchange
Figure 12. CLK_IN, SYNC_IN — SCbus Mode (CLK_IN Divider = 1)
CLK_IN (Conventional)
t1
t2
t3
SYNC_IN (Conventional)
t5
t7
t4
t6
CLK_IN (ST-BUS)
SYNC_IN (ST-BUS)
SCLKX2*
SCLK
FSYNC*
t1
t2
t3
t9
t8
t10b t11b
t10a t11a
t12
t13
Table 12. CLK_IN, SYNC_IN — SCbus Mode (CLK_IN Divider = 1)
Symbol
t1
t2
t3
t4
t5
t6
t7
t8
t9
t10a
t10b
t11a
t11b
t12
t13
Note:
Parameter
Min
Typ
Max
CLK_IN period
488
CLK_IN high time
244
CLK_IN low time
244
SYNC_IN low setup to CLK_IN↓ (PEB conventional) 10
SYNC_IN low hold from CLK_IN ↓ (PEB conventional) 10
SYNC_IN high setup to CLK_IN ↓(PEB conventional) 10
SYNC_IN high hold from CLK_IN ↓ (PEB conventional) 10
SYNC_IN setup to CLK_IN ↓ (ST-BUS)
10
SYNC_IN hold from CLK_IN ↓ (ST-BUS)
10
SCLK↑ delay from CLK_IN ↑ (PEB conventional)
25
SCLK↑ delay from CLK_IN ↓ (ST-BUS)
25
SCLK↓ delay from CLK_IN ↓ (PEB conventional)
25
SCLK↓ delay from CLK_IN ↑ (ST-BUS)
25
FSYNC*↓ delay from SCLK ↓
30
FSYNC*↑ delay from SCLK ↓
30
1. Timing measured with 200 pF load on all SCbus outputs.
Preliminary specification
SC2000
Unit
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
2000 Sep 07
34