Electrical characteristics
Table 25. Flash power supply DC electrical characteristics
Symbol
Parameter
Conditions1
Value2
Min
Typ
ICFREAD3
IDFREAD3
ICFMOD3
IDFMOD3
ICFLPW3
IDFLPW3
ICFPWD3
IDFPWD3
CC Sum of the Flash
Code Flash
current module
consumptio read
Data Flash
n on VDDHV fCPU = 64
and VDDBV MHz4
on read
access
CC Sum of the Program/ Code Flash
current Erase
consumptio on-going
Data Flash
n on VDDHV while
and VDDBV reading
on matrix Flash
modificatio registers
n
fCPU = 64
(program/er MHz4
ase)
CC Sum of the
current
consumptio
n on VDDHV
and VDDBV
during
Flash low
power
mode
Code Flash
Data Flash
CC Sum of the
current
consumptio
n on VDDHV
and VDDBV
during
Flash
power
down mode
Code Flash
Data Flash
1 VDD = 3.3 V ± 10% / 5.0 V ± 10%, TA = -40 / 125 °C, unless otherwise specified
2 All values need to be confirmed during device validation.
3 Data based on characterization results, not tested in production
4 fCPU 64 MHz can be achieved only at up to 105 °C
Max
33
33
52
33
1.1
900
150
150
Unit
mA
mA
mA
µA
µA
MPC5607B Microcontroller Data Sheet, Rev. 3
Freescale Semiconductor
39